Battery Capacity Tester Constant Current Electronic Load USB Power Supply Detector Adjustable Resistor FX25 In Pakistan
Battery Charger & Supply

Battery Capacity Tester Constant Current Electronic Load USB Power Supply Detector Adjustable Resistor FX25 In Pakistan

Condition: New
Availability: Out Of Stock
Advance Payment Only
Share:    

SKU: RAWLIXBat

Ask Price
Features:
  1. Using separate power supply design, the product itself and a display circuit measuring the electrical energy consumption of the road is not the end of the test, measurement is more accurate and reliable.
  2. A liquid crystal display screen can display the load input voltage, input current, input power, discharge time, discharge maH, product temperature, and other information.
  3. Complete protection mechanism, with under voltage protection, overvoltage protection, overcurrent protection, multiple protection over power protection, over-temperature protection.
  4. Current is adjusted by potentiometer long-handled hand rotation can be adjusted, without the need for additional tools word knives.
  5. With voltage and current correction function to meet the high precision requirements of customers.
  6. Parameters can be stored off the power.
  7. Apply to various power sources (product power, charger, charging treasure, etc.) aging or functional test, test various battery capacity discharge characteristics, desktop small load.
Detailed Features:
  • LCD display
  • In normal mode, the
    • LCD display
    • s the load input voltage and load temperature up; the downstream shows the load current, power, capacity, and discharge time. In protected mode, the
      • LCD display
      • s the protection code. In the setting mode, the
        • LCD display
        • s various setting parameter codes and parameter thresholds.
        • Load current regulation
        • The magnitude of the discharge current can be adjusted by a potentiometer.
        • Sound and light alarm
        • When the load is turned on, the RUN indicator is always on and the buzzer is not ringing. When the load is off, the RUN indicator is off and the buzzer is not ringing. After entering the protection mode, the buzzer will drop the alarm and the RUN indicator will flash.
        • Intelligent fan cooling
        • The fan automatically starts when the load discharge power is greater than 10W or the load temperature is greater than 40°C.
        • Discharge capacity and discharge time automatic statistics, as long as the load is turned on (RUN indicator is always on) to start statistics, turn off the load (RUN indicator is not lit), stop statistics, statistics support power-down storage, clear statistics only one The method is to press the '-''' button when the
          • LCD display
          • s the discharge capacity or discharge time. Please clear the statistics before starting the statistics. The maximum discharge capacity (OAH) and maximum discharge time (OHP) can be set to on or off in the setup mode, and the threshold size can be set. When the threshold is exceeded, the load is automatically turned off, enabling unattended discharge experiments.
          • Perfect software and hardware protection mechanism, and the software protection threshold can be adjusted. After software protection, the output is turned off.
          • Hardware protection:
          • Both the module power port and the load input port have anti-reverse protection.
          Software Protection:
          1. OVP - Overvoltage protection (default 25.5V, can be set by yourself, after overvoltage protection, RUN indicator flashes, LCD interface displays OVP);
          2. OCP-overcurrent protection (default 5.10A, can be set by yourself, after overcurrent protection, RUN indicator flashes,
            • LCD display
            • s OCP);
            • OPP- over power protection (default 35.5W, can be set by itself, after over power protection, RUN indicator flashes, LCD flashes OPP);
            • OTP - Over temperature protection (over temperature protection after load temperature is greater than 80 °C, RUN indicator flashes,
              • LCD display
              • s OTP);
              • LVP - Undervoltage protection (default 1.5V, can be set by yourself, after Undervoltage protection, RUN indicator flashes, liquid crystal display LVP, in battery discharge test and other applications, set the appropriate LVP, can effectively prevent battery over discharge, so as not to damage the battery)
              • The load is turned off by default. After power-on, press the ON/SET button to start or shut down.
              • All settable parameters can be stored off the power.
          Note:
          1. Please read the manual carefully before using this product! If the module is damaged due to incorrect use, or if the device is removed without authorization, it will not be returned.
          2. The power supply voltage should be DC5V, DC power supply, do not use AC power! If the voltage is overvoltage, the module may be burned after power-on;
          3. The voltage at the load input should be between DC 1.5V and 25V. The current should be below 5A (ZK-FX35).
          4. The load input port should not be short-circuited, otherwise, the product will be burnt.
          5. Be careful not to get wet of the module. Do not short-circuit the components on the board. Do not touch the pins and pads of the components on the board.
          6. Disclaimer: This product can not be used in medical, life-saving, flammable, explosive, and other fields and occasions. Our factory will not bear any responsibility for the consequences.
          Package Include:

          1XBattery Capacity Tester Constant Current Electronic Load USB Power Supply Detector Adjustable Resistor FX25

Based on 1 reviews

5

overall

Add a review

Hanzala - March 26, 2021

Ask a Question